                        Szczegóły Produktu:
                                                     
 
 | 
| Working Stability: | 0.1% Of Total Fluorescence Intensity | Model: | CAM-1000 | 
|---|---|---|---|
| Power Supply: | AC 110/220V, 50/60Hz | Measuring Chamber: | 439*300*50mm; | 
| Wavenumber Range: | 7800~375 cm-1 | Detector: | Silicon Photodiode | 
| Grating Lines: | 1800 | Wavelength Repeatability: | +/- 0.2nm | 
| Test Time: | 100-300 seconds (adjustable) | Deoxygenation Tube: | Dedicated to ECD detector | 
| Content Analysis Range: | 1ppm~99.99% | Detection Object: | Solid | 
| Instrument Resolution: | 144±5eV | Spectral Bandwidth: | 2nm | 
| Ion Source: | EI, EI/CI mixed source, CI (PCI & NCI) | ||
| Podkreślić: | CAM-1000 Condom Leak Detector,Solid Samples Condom Leak Detector,Automatic Condom Leak Detector | ||
| Attribute | Value | 
|---|---|
| Working Stability | 0.1% Of Total Fluorescence Intensity | 
| Model | CAM-1000 | 
| Power Supply | AC 110/220V, 50/60Hz | 
| Measuring Chamber | 439*300*50mm | 
| Wavenumber Range | 7800~375 cm-1 | 
| Detector | Silicon Photodiode | 
| Grating Lines | 1800 | 
| Wavelength Repeatability | +/- 0.2nm | 
| Test Time | 100-300 seconds (adjustable) | 
| Deoxygenation Tube | Dedicated to ECD detector | 
| Content Analysis Range | 1ppm~99.99% | 
| Detection Object | Solid | 
| Instrument Resolution | 144±5eV | 
| Spectral Bandwidth | 2nm | 
| Ion Source | EI, EI/CI mixed source, CI (PCI & NCI) | 
The condom leak detector is designed for rubber sleeves and condom pinhole leakage tests, meeting industry standards including GB 7544, ISO 4074, and ISO 25841.
Visual inspection method: Condoms are filled with a specific water volume and manually observed for leaks.
| Item | Parameters | 
|---|---|
| Test position | 10 | 
| Water temperature | (10℃~40℃), time (10±2)s | 
| Injection volume | (50mL~1000mL) ±10mL (automatic water injection, adjustable volume) | 
| DC voltage | (10±0.1)V | 
| Voltmeter accuracy | ±0.3mV | 
| Precision resistance | (10±0.5)kΩ | 
| Dimensions | 1000 mm (L) * 450 mm (W) * 1600 mm (H) | 
| Weight | Approx. 125kg | 
| Configuration list | Main unit workstation, measuring electrode rod, male condom test heads, female condom K.2 leak test stand | 
 
         
    Founded in 2004, Haida® is the recognized market leader in Dongguan, China for testing equipment. The company specializes in four main manufacturing series: Accelerated Environmental Series (AES), Universal Tensile Machine (UTM), Paper & Packaging (P&P), and Foam, Furniture & Optical (FFO). Haida also provides equipment for Textile & Shoes & Leather, Luggage, Baby carriage & toys, and optical testing applications.
Osoba kontaktowa: Mary
Tel: 13677381316
Faks: 86-0769-89280809